| Symptom | | Usual Causes | | Correction |
| Dark smudges on work |
| | 1. High pH 2. Low TVC MS 3. Low TVC Catalyst 4. Low chromium concentration
| | 1. Adjust pH 2. Add TVC MS 3. Add TVC Catalyst 4. Add TVC Chromium Compound
|
| White patches on work (non-uniform) |
| | 1. Lead contamination 2. Poor cleaning prior to nickel 3. Part dries prior to chromium plating
| | 1. "Dummy" solution at 15 ASF 2. Improve cleaning 3. Keep parts slightly wet
|
| White deposit at chromium cut-off |
| | 1. Zn, Pb contamination | | 1. "Dummy" at 15 ASF |
| Poor chromium adhesion |
| | 1. Bipolarity during exit from nickel solution 2. Bipolarity during chromium entrance 3. Lead contamination 4. Pre-chromium rinses contaminated with hexavalent chromium
| | 1. Exit nickel solution with some current applied 2. Enter chromium solution with some current applied 3. "Dummy" solution at 15 ASF 4. Dump rinses and remove source(s) of hexavalent chromium
|
| Poor chromium coverage |
| | 1. Low pH 2. Low specific gravity 3. Zn, Pb contamination 4. High air agitation 5. High temperature
| | 1. Correct pH 2. Add TVC Base Compound 3. "Dummy" at 15 ASF 4. Reduce air agitation 5. Reduce temperature
|
| Low chromium thickness |
| | 1. High pH 2. Low agitation 3. Low TVC Catalyst
| | 1. Reduce pH 2. Increase air agitation slightly 3. Add TVC Catalyst
|
| High voltage requirement |
| | 1. Crystallization on anodes 2. Poor electrical connections
| | 1. Dilute solution if specific gravity is high 2. Inspect and tighten loose connections
|
| Crystallization (On tank sides, anodes, piping |
| | 1. Low temperature 2. High specific gravity
| | 1. Adjust temperature 2. Dilute solution
|
| Dark deposits overall |
| | 1. High temperature 2. High pH 3. Metallic contamination
| | 1. Adjust temperature 2. Adjust pH 3. "Dummy" solution at 15 ASF
|